500kg steam generator in Linzhi Tibet

  • Frequently asked questions about Laurastar ironing systems

    Distilled water is not recommended because it is too pure and does not contain any minerals and thus no conductibility. The absence of conductibility will prevent the probe inside the boiler detecting the water level. It is thus advised to use tap water only. If you own a steam generator Laurastar Lift or Laurastar …Learn More

  • Common Steam Boiler Problems & How to Troubleshoot Repairs

    A water leak in a closed system will eventually drop the water level available for the system low enough that it will cause the system to shut down. If the water level does not decrease significantly but the system leaks, atmospheric moisture may be getting into the system. This untreated water in your tank can cause premature wear.Learn More

  • Methods of Detecting Water Level in Steam Boilers | …

    Nov 03, 2020 · Steam generators hold from 3,000 to 16,000 tubes, each about three-quarters of an inch in diameter. The water inside the tubes heats non-radioactive water on the outside, which makes steam. This non-radioactive steam turns a turbine to make electricity. The steam is then condensed back into water for another trip through the steam generator.Learn More

  • Steam Boiler: Working principle and Types of Boiler

    Feb 24, 2012 · As the water and steam both are in same vessel a fire tube boiler cannot produce steam at very high pressure.. Generally it can produce maximum 17.5 kg/cm 2 and with a capacity of 9 Metric Ton of steam per hour.. Types of Fire Tube Boiler. There are different types of fire tube boiler likewise, external furnace and internal furnace fire tube boiler.Learn More

  • Methods of Detecting Water Level in Steam Boilers | Spirax

    Low water alarm - For safe boiler operation, the low water alarm ensures that the combustion of fuel does not continue if the water level in the boiler has dropped to, or below a predetermined level. For automatically controlled steam boilers, national standards usually call for two independent low level alarms, to ensure safety.Learn More

  • Steam Boiler Maintenance Ultimate Guide | Linquip

    May 26, 2020 · If your steam boiler has probe style low water cut-offs, it should be flushed at least once a year. Plus, you need to set an appointment with your technician for annual oil burner service and cleaning. Do not try to do this yourself or you might end up hurting yourself or compromise the system.Learn More

  • Common Steam Boiler Problems & How to Troubleshoot Repairs

    A water leak in a closed system will eventually drop the water level available for the system low enough that it will cause the system to shut down. If the water level does not decrease significantly but the system leaks, atmospheric moisture may be getting into the system. This untreated water in your tank can cause premature wear.Learn More